New Step by Step Map For high performance liquid chromatography
New Step by Step Map For high performance liquid chromatography
Blog Article
As the stationary stage is polar, the cell period is really a nonpolar or simply a reasonably polar solvent. The combination of the polar stationary stage plus a nonpolar cellular phase known as usual- phase chromatography
The cell stage’s movement price is determined by the blended speeds of the two pumps. By changing the relative speeds of the two pumps, distinctive binary cell phases is often prepared.
This webpage does not exist in the picked language. Your desire was saved and you will be notified when a page is often considered in your language.
High-Performance Liquid Chromatography (HPLC) is a sophisticated analytical technique based upon chromatographic ideas of separation and interaction amongst substances and stationary and cell phases.
物質にエネルギーを与える(励起)ことにより発光する(蛍光)性質を利用した検出器。一般に選択性が高く高感度で、物質に特異的な検出が可能。蛍光する性質を持たない物質については、その物質を標識することにより検出が可能になる。
We try our best to produce This web site consumer-friendly and resourceful with well timed/up-to-date specifics of Every pathogen, sickness because of them, pathogenesis, and laboratory analysis.
The solvent reservoir retail store the solvent or mobile stage to provide to the column as required. The solvent is pumped to your column in a specific movement rate.
It achieves this by exploiting the differing interactions of sample compounds with two vital phases: the mobile stage as well as stationary phase. Comprehension the Main components of an HPLC system and their roles is important for productive click here Evaluation.
Ghost peaks are extraneous peaks that show up within the chromatogram but Do not correspond to any parts within the sample. These can complicate data Assessment. Below are a few likely results in and remedies:
원하는 분석 결과를 얻기 위해서는 컬럼도 충분히 고려하고 선택하는 것이 좋습니다.
In liquid–liquid chromatography the stationary phase is usually a liquid film coated with a packing content, typically three–10 μm porous silica particles. As the stationary section may be partly soluble within the cell stage, it may elute, or bleed from the column as time passes.
In the ionization chamber the remaining molecules—a combination website in the cellular stage factors and solutes—undertake ionization and fragmentation. The mass spectrometer’s mass analyzer separates the ions by their mass-to-charge ratio (m/z). A detector counts the ions and displays the mass spectrum.
. One issues having an isocratic elution is always that an appropriate mobile stage energy for resolving early-eluting solutes may possibly cause unacceptably extended retention instances for late-eluting solutes. Optimizing the cell stage for late-eluting solutes, However, may well supply an insufficient separation of early-eluting solutes.
Resolution: Specific injection minimizes band broadening, which can cause overlapping peaks and hinder separation.